| Type | Terminal No | Name | Terminal Funciton | Specification |
| Analog Input | AI1~AI2 | Analog inputs | Receive voltage/current input. Voltage or current are selected by DIP switch SW3 or SW1. Voltage input mode is the default mode. | Input voltage: 0~10V |
| Input current: 0~20mA | ||||
| Reference ground: GND | ||||
| AO/AO1 | Analog output | Be able to output analog voltage/current. Voltage or current are selected by DIP switch SW2. | Output voltage: 0/2~10V | |
| Output current: 0/4~20mA | ||||
| Reference ground: GND | ||||
| Analogy Output | AO2 | Analog output | Provide analog voltage/current output, with voltage and current selected by the DIP switch SW5. | Output voltage: 0/2~10V |
| Output current: 0/4~20mA | ||||
| Reference ground: GND |
| Type | Terminal No | Name | Terminal Funciton | Specification |
| Commu- nication | 485+ | RS485 interface | 485 differential signal positive terminal | Standard RS-485 communication interface, Not isolated to GND |
| 485- | 485 differential signal negative terminal | |||
|
Multi- Functional
Input Terminal |
X1~X6 | Multi-function input terminals | It can be defined as a multi-function discrete input terminal through programming. | Optical-isolator input |
| Input resistance: R=3.9kΩ | ||||
| Input voltage: 0~30V | ||||
| Reference ground: COM | ||||
| Multi _ x001f_Function Output | DO | Open collector output terminal | It can be defined as a multi-function output terminal for pulse signal through programming. It can also be used as an on-off output terminal. | Opto-coupler isolated OC output. |
| operating voltage: 0V~26V | ||||
| Maximum current: 50mA | ||||
| Output frequency: 0~50kHz | ||||
| Reference ground: COM | ||||
| Electric Replay Output | TA | Relay output | It can be defined as a multi-function relay output terminal through programming. |
TA-TB: NC TA-TC: NO
Contact capacity: 250VAC/2A (COSΦ=1.0) 250VAC/1A (COSΦ=0.4) 30VDC/1A |
| TB | ||||
| TC | ||||
| RA | Relay output |
RA-RC: NO
Contact Capacity: 250VAC/2A (COSΦ=1) 250VAC/1A(COSΦ=0.4) 30VDC/1A |
||
| RC | ||||
| PLC | Multifunctional input common terminal |
When leaving the factory, it is shorted to 24V, and the PLC is internally isolated from 24V.
Note: When using PLC, the SW4 jumper on the right side of the control terminal must be disconnected. |
X terminal supports NPN and PNP connection methods. | |
| Power | 10V | +10V power supply |
Provide +10V power supply externally
(Reference ground: GND) |
Maximum output current 20 mA
Open circuit voltage can be up to 12V |
| 24V | +24V power supply |
Provide +24V power supply externally
(Reference ground: COM) |
Maximum output current 100mA | |
| GND | +10V Reference GND | Reference GND for analog signal and +10V power supply |
Inner Isolated from COM
COM for +10V, AI1, AI2, and AO1 |
|
| COM | +24V Common GND | Used with other terminals | Isolated from GND | |
| PE | Shield ground | It is used for grounding of terminal wiring shield layer. Shield layer of analog signal lines, 485 communication lines, and motor cables can be connected to this terminal | It is internally connected to connection terminal PE of main circuit. |
| Subject | Specification |
| Rated input voltage, frequency | 3 Phase 380V-440V, 50/60Hz |
| Allowed input voltage working scope | 3 Phase 380V: 304V-456V, Voltage imbalance rate less than 3%, frequency less than +-5% |
| Rated output voltage | 0~Rated input voltage |
| Maximum overload current | Type G, 150%/min, 180%/20Sec. Type P, 120%/min, 150%/sec |
| Control mode | VF/Current vector control |
| Frequency controlling scope | Low frequency mode : 0.00-650.00Hz, High frequency mode: 0.0~1000Hz |
| Frequency accuracy | Digital command: ±0.01 %(-10°C~ +40°C) Analog command: ±0.01 %(15°C~35°C) |
| Set frequency resolution |
Digital command: 0.01 Hz
Analog command: 1/1000 maximum frequency |
| Output frequency resolution | 0.01 Hz |
| Frequency setting signal | 0~10V, 0~20mA |
| Accelerating time | 0.1-3600 Seconds |
| Braking torque | Additional braking torque up to 125% |
| Voltage / Frequency features |
4 optional fixed VF features ,
and random VF feature setting with RG VF control |
| Protection | Over-voltage, Under-voltage, Current Limit, Over-current, Overload, Electronic thermal relay , Over-heat, over-voltage with stall, short circuit load, touch ground, under-voltage protection, input default phase, output default phase, short circuit of touch ground or phases, motor overload protection, etc. |
| Ambient temperature | -10°C~40°C |
| Humidity | 5-95% RH |
| Storage | Storage-40°C~70°C |
| Working condition | Indoor without corrosive gas. |
| Installation | Altitude not higher than 1000 Meters without dust, corrosive gas and sunlight direct radiation |
| Vibration | Less than 5.9m/s 2 (0.6g) |
| Protection level | lP20 |
| Series | Model | Input Voltage | Input | Output | Motor |
| current (A) | current (A) | Power (kW) | |||
| ALPHA6000E | Three-phase 380V | 3.7 | 2.5 | 0.75 | |
| / | 5.4 | 4 | 1.5 | ||
| / | 7 | 6 | 2.2 | ||
| / | 10.7 | 9 | 4 | ||
| / | 15.5 | 13 | 5.5 | ||
| / | 20.5 | 17 | 7.5 | ||
| / | 26 | 25 | 11 | ||
| / | 35 | 32 | 15 | ||
|
/
/ |
38.5 | 37 | 18.5 | ||
|
/
/ |
46.5 | 45 | 22 | ||
| / | 62 | 60 | 30 | ||
|
/
3037GB/3037PB-N |
76 | 75 | 37 | ||
|
/
3045GB/3045PB-N |
92 | 90 | 45 | ||
|
/
3055GB/3055PB-N |
113 | 110 | 55 | ||
|
/
3075GB/3075PB-N |
157 | 152 | 75 | ||
| / | 180 | 176 | 93 | ||
| / | 214 | 210 | 110 | ||
| 3132G/3132P-N | 256 | 253 | 132 | ||
| / | 307 | 304 | 160 | ||
| / | 350 | 342 | 185 | ||
| / | 385 | 380 | 200 | ||
| / | 430 | 426 | 220 | ||
| / | 500 | 480 | 250 | ||
| 3280G/ | 548 | 520 | 280 | ||
| 3315G/3315P-N | 625 | 600 | 315 | ||
| /3355P-N | 710 | 680 | 355 | ||
| / | 760 | 750 | 400 | ||
| 3450G/ | 830 | 820 | 450 | ||
| /3500P-N | 910 | 900 | 500 | ||
| 3560G/ | 970 | 950 | 560 | ||
| /3630P-N | 1070 | 1050 | 630 |
•