Specification
| Model | NV-16W | NV-21W | |||||
| Rated voltage | AC250V | DC125V | DC250V | AC250V | DC125V | DC250V | |
| Resistive load | 16A | 0.6A | 0.3A | 21A | 0.6A | 0.3A | |
| Light load | 2A | 0.1A | 0.05A | 3A | 0.01A | 0.05A | |
| Inductive load | 10A | 0.6A | 0.3A | 12A | 0.6A | 0.3A | |
| Motor load | 4A | 0.1A | 0.05A | 6A | 0.1A | 0.05A | |
| Contact appearance | Rivet | ||||||
| Contact material | AgSnO2 | ||||||
| Min applicable load | DC5V 160mA | ||||||
| Operating speed | 0.1mm~1m/s | ||||||
| Permissible operating frequency | Mechanical:200 operations/min Electrical:30 operations/min | ||||||
| Contact resistance | 30mΩ max. (Initial value) | ||||||
| Insulation resistance | 100mΩ min.(at DC500V) | ||||||
| Dielectric strength | 1000V, 50/60Hz 1min between terminals of the same polarity | ||||||
| 1500V, 50/60Hz 1min between each terminal and no-current-carrying metal parts | |||||||
| 1500V, 50/60Hz 1min between current-carrying metal parts and ground | |||||||
| Protection grade / PTI | IEC IP40 / 175 | ||||||
| Protection grade of electric shock | Class | ||||||
| Operating ambient |
Temperature: -25°C ~ 125°C(with no icing or condensation)
Humidity: 60% RH max. |
||||||
| Endurance |
Mechanical: 1,000,000 operations min.
Electrical: 50,000 operations min. |
||||||
| Operation chatacteristics | NV-16W | NV-21W | |
| Operating force | OF Max. | 1.23N/0.59N | 2.45N |
| Releasing force | PF Min. | 0.14N/0.06N | 0.25N |
| Pre-travel | PT Max. | 4.0mm | |
| Over-travel | OT Min. | 1.6mm | |
| Movement differential | MD Max. | 1.5mm | |
| Operating position | OP | 18.7±1.2mm | |