High voltage! |
Any touch with bare hand against high voltage at input side is forbidden. |
| Caution | The device shall be securely grounded before power-on. |
|
High voltage! |
Any operation at AC & high voltage under lightning is forbidden. |
| Environment | |||||
| Parameter | Min. | Typ. | Max. | Unit | Remark |
| Operation temperature | -25 | 70 | ° C | For high temperature of 60 ºC - 70 ºC , with 80% load derating. | |
| Storage temperature | -45 | 85 | ° C | ||
| Relative humidity | 10 | 95 | % | ||
| Altitude | ≤ 5000 | m | |||
| Input | ||||||
| Parameter | Min. | Typ. | Max. | Unit | Remark | |
| Input voltage range | 85 | 220 | 265 | Vac |
Or
120
-
370VDC
For convenience of certification,inpput voltage range on product label marked as 100 - 240 Vac . 85 - 265 Vac at testing . For low-voltage of 85-100Vac input,test with 80 % load derating . |
|
| Input frequency range | 47 | 50 | 63 | Hz | ||
| Input power factor | 0.95 | % | ,, full-load | |||
| Input curren t | 5 | A | 3.5Adc | |||
| Surge current | 30 | A | ≤ , ≤ | |||
| Surge voltage | KV | line - ground 4KV , line - line 2KV(class A) | ||||
|
Drain voltage
( ) |
115Vac | 0.25 | 0.75 | mA | ||
| 230Vac | 0.5 | |||||
| Output | ||||||
| Parameter | Min. | Typ. | Max. | Unit | Remark | |
| Output voltage range | 20 | 2 4 | 28.8 | V | adjustable ( 20V ~ 24V with 13A load ,25V ~ 26V with 11A load , 26-28.8V with 9A load , for setting value and other s pecification test: 24V/13A .), The output voltage be in the range of 24 ± 0.2V at delivery. | |
| Output current range | 13 | A | Refer to stabilized cu rrent output range. | |||
| Startup time | 5 | S | ||||
| Load regulation | ± 1 | % | ||||
| Stabilized voltage precision | ± 1 | % | ||||
| Source regulation | ± 1 | % | ||||
| Ripple&noise | 150 | mV | mVp-p | |||
| Output power range | 312 | W | full-load output | |||
| Output indicator | φ 5 | mm | Green light on when DC output normally | |||
| Temperature coefficient | ± 0.02 | %/ ºC | ||||
| full-load efficiency | 85 | % | 220Vac, full-load | |||
| 82 | 110Vac, full-load | |||||
| Hold-up time | 20 | mS | 100V ~ 240Vac, full-load , phase angle of 45 ° , duration for AC input powerdown to output voltage dip to 90% .. | |||
| Cap acitive load | 5000 | uF | The power supply shall startup normally and operate stably . | |||
| Inductive load | ,, printer and so on | The power supply shall startup normally and operate stably . | ||||
| Dynamic response | R ecovery time | 500 | uS | 25%-50%-25%,0.25A/uS, cycle 2m S | ||
| 500 | uS | 50%-75%-50%,0.25A/uS, cycle 2mS | ||||
| Overshoot amplitude | ± 5 | % | 25%-50%-25%,0.25A/uS, cycle 2mS | |||
| ± 5 | % | 50%-75%-50%,0.25A/uS, cycle 2mS | ||||
| Protection | |||||
| Parameter | Min. | Typ. | Max. | Unit | Remark |
| Input over-voltage protection voltage | 270 | 280 | 290 | V | Remove this function,but the power supply shall work stably for shorttime under 300Vac input |
| Input over-voltage protection recovery voltage | 265 | 270 | 280 | V | |
| Input under-voltage protection voltage 90 | 65 | 75 | 80 | V | |
| Output under-voltage protection recovery voltage | 75 | 85 | 90 | V | |
| Output over-voltage protection | 30 | 34.8 | V | ||
| Output o ver-current protection | 17 | A |
Constant current,auto
-
recoverable.
Conduct protection after 100ms when the current > 17A , Vo before protection > 16.8V , Vo after protection be less than 4V . |
||
| Short-circuit protection | Protection when short-circuit,auto-recoverable. | ||||
| Over-temperature protection | ºC | With over-temperature protection function. | |||
| EMC and others | ||
| Parameter | Standard and requirement | |
| CE | EN55022:1998 - Class B ( pure resistance load ) | |
| RE | EN55022:1998 - Class B ( pure resistance load ) | |
| SURGE | IEC61000-4-5:1999 , line - line 2KV , line - ground 4 KV ( criterion A) | |
| ESD | IEC61000-4-2:2001 Contact discharge :± 6KV , air discharge :± 10KV . ( criterion A ) | |
| RS | IEC61000-4-3:2002 Test LEVEL 10V/m | |
| CS | IEC61000-4-6:2001 Test LEVEL 10V | |
| EFT/B | IEC61000-4-4:2004 LEVEL 3 B Class | |
| Vib ration & Impact | Vibration | 10Hz ~ 55Hz , acceleration : 19.6m/s 2 3 directions for 1 hour |
| Impact | Half sine-wave , peak acceleration : 20G , pulse width : 11m , S , X , Y , Z directions , 3 times per direction. | |
| Startup & shutdown impact | ≥ 1000 times , 25 ºC 115Vac , full-load , 3S/on , 3S/off , without damage. | |
| DIP | IEC61000-4-11:1994 voltage dip to 0 %, duration: 5000mS ( 250 cycles ) ;( criterion C ) | |
| IEC61000-4-11:1994 voltage dip to 70 %, duration: 500mS ( 25 cycles ) ; 0 °, 45 °, 90 °, 135 °, 180 °, 225 °, 270 °, 315 ° Meet ( criterion C ) | ||
| IEC61000-4-11:1994 voltage dip to 40 %, duration: 100mS ( 5 cycles ) ; 0 °, 45 °, 90 °, 135 °, 180 °, 225 °, 270 °, 315 ° Meet ( criterion C ) | ||
| IEC61000-4-11:1994 voltage dip to 0 %, duration: 10mS ( 0.5 cycles ) ; Meet ( criterion B ) | ||
| Harmonic current | IEC 61000-3-2 : 2001 3 subharmonic current <2.3A, others refer to Standar d (1.14 , 0.77 , 0.4 , 0.33 , 220 , 15*15/ n) | |
| Voltage fluctuation & flicker | IEC61000-3-3 : 1994 Pst ≤ 1.0,P1t ≤ 0.65, relative stable voltage change ≤ 3%, max.chage ≤ 4%, duration for d(t) exceed 3% is less than 200mS | |
| Cooling | Cooled by fan,keeping the inside temperature < +65 ºC | |
| Audible noise | ≤ 50dB ; 25 ºC full-load , test at 100cm | |
| MTBF | MTBF ≥ 100,000h , 90V-14V , 110V-14A , 220V-14A , 260V-14A | |
| Safety | The chassis and heat sink are electrically neutral , without peculiar and deleterious odor. | |
| Chassis | With earth pole φ 4 | |
| Safety and Insulation Rating | ||
| Parameter | Standard | Remark |
| Input - output | 3000Vac/10mA//60min |
No flashover or breakdown
The discharge tube shall be removed before test. |
| Input - ground | 2000Vac/10mA//60min | |
| output - ground | 500Vdc/10mA//60min | |
| Ground resistance | < 0.1 Ω | |
| Insulation resistance | ≥ 100M Ω |
At normal atmospheric pressure,
relative humidity: 90%; Testing voltage: 500v DC; The insulation resistance of input-output,input-ground,output-ground shall not be less than 100M Ω |
| Contact current | To enclosure ≤ 1.75mA to output ≤ 0.25mA | 264V/60Hz |
| Ground impedance | ≤ 0.1 Ω 32A/2 min | |
| PCB | Conform to UL94V-0 Standard | Inflaming retarding. |